
Shut off the water, take the head assembly off the faucet and store it indoors, open the ends of the lines and let them drain, then loosely put the caps back on. Do it before the first freeze. That is the whole job for most home drip systems β Iowa State University Extension's winter-care guidance is exactly that sequence: disconnect the system from the water source, remove the complex components and store them indoors, remove the end caps and lift the hoses so the water drains out. Water left inside freezes and breaks hoses, emitters, and pipes β and the rigid parts at the faucet are the vulnerable ones: Colorado State University Extension notes that poly mainline "will not be damaged by freezing" once drained, while the timer, filter, regulator, and backflow preventer must be stored indoors.
Sophie: It survived the whole summer outside. Why does it suddenly need to come inside in November?
Sprouty: The tubing can stay out β it is the hard bits that cannot. The timer, the filter, the pressure regulator, the backflow preventer: they are little sealed boxes full of water, and frozen water does not negotiate. Drain the lines, bring the boxes in, and the system sleeps fine until spring.
When to winterize: before the first freeze
The deadline is the first freeze, not the first frost, and the two are not the same night. Frost is 32Β°F or lower, and a hard freeze β 28Β°F or lower β is the more damaging event, as our guide to California's first frost explains. University of Georgia Extension's winterization checklist puts the timing plainly: drain the system "preferably before the first freeze." But the first freeze is the deadline, not the warning: once water is frozen inside a sealed timer or a closed valve, the damage is already done.
Timing depends entirely on where you garden. University of Vermont Extension's fall checklist, published November 16, 2026, lists winterizing in-ground watering systems as a now job β Vermont nights were already dipping below freezing. In California the window is later and wider: UC Agriculture and Natural Resources' frost-date table (historical averages built from 1971β2000 National Weather Service data) puts the early first frost at November 6 in Fresno and December 4 in Sacramento, while coastal towns like Alameda, Berkeley, and San Diego average 365 frost-free days a year β frost may never arrive at all. Plan by the early date for your town, not the median: our guide to California's first frost explains why the early date is the one that catches people out.
The practical rule: winterize when the forecast first shows a night at or below freezing, and do not wait for the second one. If a freeze catches you unprepared, the emergency version is short β shut off the water, pull the head assembly off the faucet, and open the line ends. The hands-on part takes about ten minutes, though the lines still need hours to drain fully, so do it as soon as the freeze is forecast, not the night it arrives.
First, know what you are winterizing
A drip system has two halves, and they winterize differently. At the faucet sits the head assembly: the parts that clean, slow, and control the water before it reaches the beds. In a permanent system, Colorado State University Extension gives the order as backflow prevention device, control valve, filter, then pressure regulator. In a faucet-attached kit the same parts hang off the hose bib, usually with a battery timer in front of them. Everything past that point is tubing and emitters running out to the plants.

The distinction matters because the two halves have opposite tolerances. The head assembly is a cluster of rigid, sealed chambers β a timer body, a filter housing, a regulator β and any one of them can crack when the water inside it freezes. The tubing is flexible polyethylene; Colorado State notes that poly mainline "will not be damaged by freezing" once it is drained, and that most emitters store well outdoors over winter. So the job is not "bring the whole system inside." It is: bring the rigid boxes inside, and get the water out of everything else.
Winterizing a faucet-fed drip kit, step by step
This is the routine for the common home setup: a kit or assembled system hanging off an outdoor faucet, feeding beds or containers. The hands-on work is short β roughly twenty minutes for a typical faucet-fed kit β but the drain itself takes several hours, so start in the morning and refit the caps only once water has stopped coming out of the open ends.
1. Flush the lines with the ends open. Clean the filter first, then remove the cap from the end of each lateral line and flush the system at full pressure, so grit and sediment exit through the open ends instead of lodging in the emitters β that is Iowa State's flushing method. UGA's farm-scale checklist flushes the same way, with the drain valves open, using a 2-ppm chlorine solution; for a home system, clean water at full pressure does the job, and if you do use a chlorine flush, never mix bleach with acids or ammonia, which form irritating and toxic compounds. If your system has a fertilizer injector, unhook the tank and run clean water through the injector lines now β concentrated fertilizer left in the lines over winter precipitates into salts that clog injectors and corrode metal parts.
2. Shut off the water and release the pressure. Close the faucet, or the irrigation isolation valve β the shut-off on the pipe where the drip system branches off the house supply β if your system has one. Then open a zone or crack a valve so the pressure in the lines drops to nothing before you start unscrewing fittings β a pressurized line will spray you, and a pressurized filter housing can be hard to open. UGA advises opening all valves as part of winterization: closed gate and ball valves trap water, and trapped water can crack the valve body when freeze-thaw cycles repeat. For solenoid valves, unscrew the bleeder knob β usually located on the top of the valve β a quarter to a half turn, or unscrew the solenoid itself, the part with the wires protruding, a quarter turn, to leave the valve open.
3. Remove the head assembly and bring it indoors. Unscrew the timer, filter, pressure regulator, and backflow preventer from the faucet as one assembly if they come off together, or piece by piece. Tip the water out of each part. Take the batteries out of the timer before storing it β timers are stored without batteries over winter, and fresh batteries go in at spring startup. Clean the filter screen now, while you are holding it, rather than discovering a clogged screen in spring. Colorado State's winterization guidance is a single sentence: detach the head assembly β control valve, backflow prevention device, filter, and pressure regulator β and store it indoors for winter. Iowa State says the same for pressure valves, timers, regulating disks, and backflow preventers. Store the assembly in a dry, frost-free spot β a garage shelf, not an unheated shed that freezes anyway β and keep the washers with their fittings so spring reassembly is not a scavenger hunt.
4. Open the ends of the lines and drain them. The ends are already open from step 1 β leave them open β and open the drain valves at the low points of the system, and let the water run out. Colorado State adds a design tip worth knowing for next spring: put at least one emitter at the lowest point of the system, or install a valve there, so the lines can be drained. Lift sagging sections of tubing a few feet at a time so trapped water runs downhill toward the open end. Iowa State warns that low areas can unintentionally trap water, and that a full drain "may take several hours" β give it the afternoon, and refit the caps only once water has stopped coming out.

5. Leave the valves open for winter. Every valve you opened in step 2 stays open. A closed valve is a sealed pocket of water; an open valve is a drain. This is the step people skip because an open valve looks unfinished β it is the point.
6. Loosely put the end caps back on. Once the lines are drained, refit the end caps loosely β tight enough to keep dirt, debris, and insects out, loose enough that any water still inside can keep draining. Iowa State is explicit: "loosely fit end caps back on to prevent debris from entering the system." Never leave the lines wide open all winter; anything that crawls in will be waiting for you in spring.
7. Inspect, note, and clean up. Winterization is the year's best inspection moment: the system is in your hands and the beds are empty. UGA recommends noting any damaged or worn parts now and replacing them before spring, when you will want the system running rather than shopping for fittings. Drain, inspect, and clean the filters. Coil any garden hoses loosely β the supply hoses, not the drip lines β and store them under cover: UVM Extension advises disconnecting, draining, and inspecting hoses, then coiling them loosely and storing them in a garage or shed.
Do you need to blow out the lines with compressed air?
Maybe β and for most home kits, no. Gravity draining handles the great majority of faucet-fed drip systems, because the tubing is flexible, the runs are short, and the water has somewhere to go. Two cases call for air. Colorado State says systems with many right-angle fittings may retain water and require pressurized air to blow out, and the same applies if your system has check valves, which hold water by design. If your lines drain fully by gravity β water stops coming out of the open ends and the low spots are lifted dry β you are done.
If you do use a compressor, the pressure limit for drip is far lower than most people expect. Iowa State puts the range at 20 to 30 psi, and warns that air pressure above 30 psi "is likely to damage emitters and other delicate parts." With the head assembly already removed, connect the compressor at the open mainline inlet where the assembly was attached, using a blow-out adaptor if your system has one, and keep the pressure at 20 to 30 psi. Check the manufacturer's guidance for your own parts. And if the blow-out feels like a job for a specialist, it is β hire a pro rather than guessing at the pressure.
Mild-winter California: the shorter version
If you garden where hard freezes are rare, the job is shorter but not optional. Colorado State's verdict on drip winterization is that the tasks are "minimal": detach the head assembly and store it indoors, uncap the mainline to drain, then re-cap. The poly tubing and most emitters can stay out all winter once drained. That is the whole California routine in most years β the hands-on work is about twenty minutes, the faucet hardware comes in, the lines drain, and the caps go back on once the water has stopped.
Two California caveats. First, "mild winter" does not mean "no freeze." The UC frost table shows inland valleys freezing regularly β Fresno's early first frost is November 6, Sacramento's is December 4 β and a sealed timer or valve with water frozen inside it is damaged once that water freezes, which is why Iowa State says to drain systems before winter to prevent water from freezing and breaking hoses, emitters, and pipes. The vulnerable part is always the rigid hardware standing above ground, not the tubing in the soil. Second, if you keep watering through winter β cool-season vegetables, newly planted natives, containers β winterize only the zones you are shutting down. UGA notes that systems kept running for cool-season crops are not winterization candidates at all; drain the idle zones and leave the working ones alone. Our winter cover crop guide covers what is still growing while the rest of the garden sleeps.

Soaker hoses get the easy version
Soaker hoses are the simplest drip system to winterize, because there is almost nothing to them. Iowa State notes that in some home garden settings "it may be easiest to simply pick up the entire system, allow it to drain, and store it indoors." Disconnect the hose, let it drain fully, coil it loosely without tight kinks, and store it under cover. A soaker hose left out all winter with water in it can crack or split when that water freezes.
What not to do
- Don't leave the timer on with the water off. A controller that tries to run dry zones all winter wastes batteries. Turn the controller off or to rain-off once the water is shut off.
- Don't leave valves closed with water behind them. UGA warns that closed gate and ball valves trap water and "can crack/break when repeated freeze/thaw cycles occur." Open every valve and leave it open.
- Don't blow out drip lines at high pressure. Iowa State caps it at 30 psi β anything above that is likely to damage emitters and delicate parts. Drip is not a lawn sprinkler system, and it does not take sprinkler pressures.
- Don't leave the end caps off all winter. Open ends invite dirt, debris, and insects. Iowa State's rule is to loosely refit the caps once the lines are drained.
- Don't skip the filter. Drain it, rinse the screen, and clean it now β UGA's checklist includes draining, inspecting, and cleaning the filters as a standard step.
- Don't forget the hose on the faucet. A garden hose left connected to an outdoor faucet traps water against the faucet itself. UVM Extension's fall checklist pairs the two jobs: winterize the in-ground watering systems and detach from outdoor faucets.
Spring restart
When the frost risk has passed, the restart is the winterization in reverse β and it is quick precisely because you did the autumn work. Colorado State's spring routine: flush the mainline to clear accumulated dirt, clean the filter, cap the system, pressurize it, and check the emitters. Reattach the head assembly, put the timer batteries back in, open the faucet, and walk the beds watching for emitters that are clogged or missing. Most emitters store well outdoors over winter and only occasional replacement is necessary, per Colorado State β replace the occasional one, and you are watering again before the coffee gets cold.
Quick answers
When should I winterize my drip irrigation?
Before the first freeze β UGA Extension says "preferably before the first freeze." In California that means watching your town's early first-frost date: Fresno's is November 6, Sacramento's December 4, and coastal towns may never freeze at all, per the UC frost table.
Do I have to blow out my drip lines with compressed air?
Usually not. Gravity draining β open ends, lifted low spots, several hours β clears most home systems. Use air only if the system has many right-angle fittings or check valves that hold water, per Colorado State, and keep it at 20 to 30 psi: Iowa State warns that pressure above 30 psi is likely to damage emitters.
Can the drip tubing stay outside all winter?
Yes, once drained. Colorado State says poly mainline "will not be damaged by freezing" and most emitters store well outdoors over winter. What comes indoors is the rigid head assembly: timer, filter, pressure regulator, and backflow preventer.
What do I do with the timer?
Disconnect it, drain it, take the batteries out, and store it indoors in a dry, frost-free place β Iowa State lists timers among the complex components to remove and store indoors. Timers are stored without batteries over winter; fresh batteries go in at spring startup.
My drip zones are buried or share plumbing with lawn sprinklers. Is this different?
Yes β buried lines cannot be lifted to drain, and a shared system drains as one system. Treat the drip zones as part of the sprinkler system's winterization job, not a separate one, and check the installer's manual β or ask the installer β how the buried lines are drained or blown out before you open any fittings.
Do I winterize a system I use all winter?
No. UGA notes that zones kept running for cool-season crops are not winterization candidates. Winterize only the zones you shut down, and keep watering the ones still in use.
Which parts are most vulnerable if I forget?
The rigid head-assembly parts: the timer body, the filter housing, the pressure regulator, and the backflow preventer. They are sealed chambers full of water, and Iowa State says to drain systems before winter to prevent water from freezing and breaking hoses, emitters, and pipes. The flexible poly tubing in the beds is the most forgiving part of the system β Colorado State says poly mainline "will not be damaged by freezing" once drained.





